LEV 160 HALOGEN FREE
Applications
ElectromechanicsRevision number
6
Review date
27/11/2017 00:00:00
Realization
Rubber cables
Description
Flexible, single-core, rubber insulated sheath cables, based on vinyl acetate, for indoor networks. Compound with a vinyl acetate base, suitable for the insulation of conductors having no sheath. Low halogenic content rubber, with high oxygen index. No-flame propagation cable, excellent mechanical and oil resistance.
Elettro Brescia S.p.A.
DATA SHEET
Technical data
Nominal tension | 300/500 V sect. 0,35-1,00 450/750 V sect. = 1,5 |
---|---|
Conditions of employment | Cable produced with a low-halogenic compound and high oxigen index and, therefore, against flame propagation. With an exellent mechanical varnishes and oil resistance it is also used in the electric motors, in the transformers, in the condenser, in the household electrical appliances, in the lamps, in the resistors and in some particulars of the cars. Used in electric motors. |
Type of electrical conductor | Flexible tinned copper |
Type of insulation | 9 |
Color of the outer sheath | On demand (one or two colours) |
Operating temperature | -40° C | +160° C (not continuous) |
Short circuit temperature | +200° C on the conductor (max 5 sec.) |
Test voltage | 2000 V |
Cable marking | ELETTRO BRESCIA (section) mm² LEV 160 HALOGEN FREE |
Minimum radius of curvature | 6 times the max outer diameter. |
Note | MECHANICAL PROPERTIES AFTER AGEING (AIR OVEN 240 h, 140° C): Tensile strength: -25% max of the value before ageing Elongation: -25% max of the value before ageing HOT SET TEST (MANDREL IN AIR OVEN 12 h, 140° C): Mandrel diameter: Same diameter of the cable Results: No cracks |
Reference standards
Conductor | EN 60228; IEC 60228 |
---|---|
Self-extinguishing | EN 60332-1-2; IEC 60332-1-2 |
Tabella sezioni
Nominal section | Max wire diameter | Conductor diameter | Insulation thickness | Insulation diameter ± 0.1 | Minimum average external diameter | Average diameter ± 0.1 | Minimum average external diameter | Maximum average external diameter | Copper electrical resistance 20°C | Approximate weight |
---|---|---|---|---|---|---|---|---|---|---|
(Nxmm2) |
(mm) |
(mm) |
(mm) |
(mm) |
(mm) |
(mm) |
(mm) |
(mm) |
(Ω/km) |
(kg/km) |
1x0,50 |
0,21 |
NA |
0,60 |
NA |
NA |
2,1 |
NA |
NA |
NA |
8,80 |
1x0,75 |
0,21 |
NA |
0,70 |
NA |
NA |
2,4 |
NA |
NA |
NA |
12,10 |
1x1,00 |
0,21 |
NA |
0,70 |
NA |
NA |
2,5 |
NA |
NA |
NA |
14,40 |
1x1,50 |
0,26 |
NA |
0,70 |
NA |
NA |
2,8 |
NA |
NA |
NA |
19,00 |
1x2,50 |
0,26 |
NA |
0,70 |
NA |
NA |
3,4 |
NA |
NA |
NA |
30,20 |
1x4,00 |
0,31 |
NA |
0,80 |
NA |
NA |
4,2 |
NA |
NA |
NA |
47,20 |
1x6,00 |
0,31 |
NA |
0,80 |
NA |
NA |
4,8 |
NA |
NA |
NA |
65,60 |