H07RN-F ECA

product

H07RN-F ECA

Applications
Appliances Lighting Technology Power Tools
Review date

23/2/2018 00:00:00

Realization

Rubber cables

Description

Flexible single and multicore power cables, rubber insulated, under heavy polychloroprene sheath or other equivalent elastomer sheath.

MaterialsRubber Certifications images images
Elettro Brescia S.p.A.

DATA SHEET

Technical data

Nominal tension

450/750 V

Conditions of employment

Use in industrial and agricultural workshops, building sites, for heavy duty applications and supplying industrial and agricultural machines and appliances where cables are subject to medium mechanical stresses (e.g. heating plates, inspection lamps, electric tools such as drills, circular saws, and domestic electric tools) use in dry, humid or moist rooms; fixed installations e.g. on rough-cast in temporary buildings and huts for accommodation purposes.

Type of electrical conductor

Flexible red copper

Type of insulation

3

Type of outer sheath

3

Color of the outer sheath

Black

Operating temperature

-25° C | +60° C

Short circuit temperature

+200° C on the conductor (5 sec. max)

Test voltage

2500 V

Cable marking

ELETTRO BRESCIA IEMMEQU H07RN-F ECA

Minimum radius of curvature

If the outer diameter of the cable is between 8 and 12 mm: 4 times the max. outer diameter in case of non-constrained motion, and 3 times in case of fixed installation. If the outer diameter is greater than 12 mm: 5 times the max. outer diameter in case of non- constrained motion and 4 times in case of fixed instalIation.

Note

For single core cables with section above 35 mm² and multicore cables with section above 10 mm², the production is possible through a commercial partner with minimum batch sizes and delivery dates to be arranged.

Reference standards

Main rule

EN 50525-2-21

Conductor

EN 60228; IEC 60228

Self-extinguishing

EN 60332-1-2; IEC 60332-1-2

Oil resistance

EN 60811-404; IEC 60811-404

Tabella sezioni

Nominal section Max wire diameter Conductor diameter Insulation thickness Insulation diameter ± 0.1 Minimum average external diameter Average diameter ± 0.1 Minimum average external diameter Maximum average external diameter Copper electrical resistance 20°C Approximate weight

(Nxmm2)

(mm)

(mm)

(mm)

(mm)

(mm)

(mm)

(mm)

(mm)

(Ω/km)

(kg/km)

2x1,00

0,21

NA

0,80

NA

1,30

8,4

7,7

10,0

19,50

115,00

2x1,50

0,26

NA

0,80

NA

1,50

9,4

8,5

11,0

13,30

140,00

2x2,50

0,26

NA

0,90

NA

1,70

11,0

10,2

13,1

7,98

200,00

2x4,00

0,31

NA

1,00

NA

1,80

12,6

11,8

15,1

4,95

275,00

2x6,00

0,31

NA

1,00

NA

2,00

14,2

13,1

16,8

3,30

365,00

3G1,00

0,21

NA

0,80

NA

1,40

9,0

8,3

10,7

19,50

135,00

3G1,50

0,26

NA

0,80

NA

1,60

10,1

9,2

11,9

13,30

170,00

3G2,50

0,26

NA

0,90

NA

1,80

11,8

10,9

14,0

7,98

240,00

3G4,00

0,31

NA

1,00

NA

1,90

13,5

12,7

16,2

4,95

335,00

3G6,00

0,31

NA

1,00

NA

2,10

15,2

14,1

18,0

3,30

445,00

4G1,00

0,21

NA

0,80

NA

1,50

9,9

9,2

11,9

19,50

165,00

4G1,50

0,26

NA

0,80

NA

1,70

11,1

10,2

13,1

13,30

205,00

4G2,50

0,26

NA

0,90

NA

1,90

12,9

12,1

15,5

7,98

290,00

4G4,00

0,31

NA

1,00

NA

2,00

14,8

14,0

17,9

4,95

420,00

4G6,00

0,31

NA

1,00

NA

2,30

16,9

15,7

20,0

3,30

565,00

5G1,00

0,21

NA

0,80

NA

1,60

11,0

10,2

13,1

19,50

205,00

5G1,50

0,26

NA

0,80

NA

1,80

12,2

11,2

14,4

13,30

255,00

5G2,50

0,26

NA

0,90

NA

2,00

14,2

13,3

17,0

7,98

360,00

5G4,00

0,31

NA

1,00

NA

2,20

16,5

15,6

19,9

4,95

520,00

5G6,00

0,31

NA

1,00

NA

2,50

18,7

17,5

22,2

3,30

695,00

Elettro Brescia S.p.A.