Unbraided non-sheathed heat resistant silicone rubber insulated cable.

MaterialsSilicone Certifications images images
Elettro Brescia S.p.A.

DATA SHEET

Technical data

Nominal tension

300/300 V

Conditions of employment

Internal wiring and in protected locations at high ambient temperatures limited by maximum conductor temperature in normal use of 180 °C.

Type of electrical conductor

Flexible tinned copper

Type of insulation

1

Color of the outer sheath

According to standard

Operating temperature

-25° C | +180° C

Short circuit temperature

+350° C on the conductor (max 5 sec.)

Test voltage

2000 V

Cable marking

ELETTRO BRESCIA IEMMEQU H03S-K 1 x section

Reference standards

Main rule

EN 50525-2-41

Conductor

EN 60228; IEC 60228

Tabella sezioni

Nominal section Max wire diameter Conductor diameter Insulation thickness Insulation diameter ± 0.1 Minimum average external diameter Average diameter ± 0.1 Minimum average external diameter Maximum average external diameter Copper electrical resistance 20°C Approximate weight

(Nxmm2)

(mm)

(mm)

(mm)

(mm)

(mm)

(mm)

(mm)

(mm)

(Ω/km)

(kg/km)

1x0,50

0,21

NA

0,60

NA

NA

NA

2,0

2,7

NA

NA

1x0,75

0,21

NA

0,60

NA

NA

NA

2,1

2,8

NA

NA

1x1,00

0,21

NA

0,60

NA

NA

NA

2,2

3,0

NA

NA

1x1,50

0,26

NA

0,70

NA

NA

NA

2,8

3,6

NA

NA

1x2,50

0,26

NA

0,80

NA

NA

NA

3,3

4,3

NA

NA

Elettro Brescia S.p.A.