material: SILICONE
tipology: SINGLECORE

AWM STYLE 3135

Appliance Wiring Material

Flexible tinned copper
    certificates

Applications
Appliances Cables

Conditions of employment
Internal wiring of appliances where totally enclosed.

Type of electrical conductor
Flexible tinned copper

Main rule
UL 758, CSA C22.2 No. 210

Self-extinguishing
FT1, FT2, VW-1


Description

Single core flexible cable with tinned copper conductor and silicone rubber insulation. UL Style 3135. cUL Class I, Group A.

More informations




Technical Specifications:   Download

Review number n. 5 - 6/9/2018
Nominal tension 600 Vac
Type of insulation Silicone rubber
Color of the outer sheath On demand
Operating temperature 200° C
Test voltage 6000 V
Cable marking ELETTRO BRESCIA RU AWM 3135 xAWG 200C 600V E487521 CRU AWM I A 200C 600V FT1 VW-1
Insulation tolerance ± 0,1


Sections
Nominal section Max wire diameter Conductor diameter Insulation thickness Average sheath thickness Average diameter ± 0,1 Copper electric resistance 20°C Indicative weight CU Factor
(Nxmm2) (mm) (mm) (mm) (mm) (mm) (Ω/km) (kg/km) (kg/km)
1xAWG24 0,51 0,51 0,76 NA 2,10 89,30 NA 1,92
1xAWG22 0,40 0,79 0,76 NA 2,35 59,40 NA 3,552
1xAWG20 0,40 1,02 0,76 NA 2,60 36,70 NA 5,952
1xAWG18 0,40 1,21 0,76 NA 2,80 23,20 NA 8,352
1xAWG16 0,40 1,52 0,76 NA 3,10 14,60 NA 13,248
1xAWG15 0,40 1,72 0,76 NA 3,30 11,50 NA 16,8
1xAWG14 0,40 1,89 0,76 NA 3,50 9,15 NA 20,448
1xAWG12 0,40 2,39 0,76 NA 4,00 5,75 NA 32,544