material: SILICONE
tipology: SINGLECORE

N2GFA (N)2GFA

Silicone cables

Solid tinned copper
    certificates

Applications
Appliances Cables

Conditions of employment
Highly resistant to heath, flexibility, excellent mechanical resistance. Suitable for harnesses for electric and electronic equipment, lighting equipment, lamp holders and in all other sectors where good technical characteristics are required and high safety standards.

Type of electrical conductor
Solid tinned copper

Main rule
VDE 0250 TEIL 502


Description

Solid single core cable with a silicone rubber insulating sheath.

More informations




Technical Specifications:   Download

Review number n. 5 - 30/4/2011
Nominal tension 300/300 V
Type of insulation EI2
Operating temperature -60° C | +180° C
Short circuit temperature 350° C on the conductor (max 5 sec.)
Test voltage 2000 V
Cable marking ELETTRO BRESCIA <VDE> / ELETTRO BRESCIA <VDE> Reg. Nr. 7874
Insulation tolerance ± 0,2


Sections
Nominal section Max wire diameter Conductor diameter Insulation thickness Average sheath thickness Average diameter ± 0,2 Copper electric resistance 20°C Indicative weight CU Factor
(Nxmm2) (mm) (mm) (mm) (mm) (mm) (Ω/km) (kg/km) (kg/km)
1x0,50 0,80 0,80 0,60 NA 2,1 36,70 NA 4,8
1x0,75 1,00 1,00 0,60 NA 2,3 24,80 NA 7,2
1x1,00 1,13 1,13 0,60 NA 2,4 18,20 NA 9,6
1x1,50 1,35 1,35 0,70 NA 2,9 12,20 NA 14,4
1x2,50 1,75 1,75 0,80 NA 3,5 7,56 NA 24