material: PVC
tipology: SINGLECORE

DUALFLEX

Cable for welding machines

Flexible red copper
    certificates

Applications
Welding Cables

Conditions of employment
For secondary side connection of powers sources for hand or automatic metal-arc welding for secondary voltage typical of welding equipment.

Type of electrical conductor
Flexible red copper

Main rule


Self-extinguishing
EN 60332-1-2; IEC 60332-1-2


Description

PVC double insulated cables for welding machines.

More informations





Review number n. 4 - 23/2/2011
Nominal tension 450/750 V
Type of outer sheath TM2
Color of the outer sheath White, orange
Operating temperature max 70° C
Short circuit temperature 160° C
Cable marking DUALFLEX (sezione) mm² CE
Minimum radius of curvature For cables with diameter up to 12 mm: 6 times the max. outer diameter in case of nonconstrained motion and 5 times in case of fixed installation. For cables with greater diameter: 7 times the max. outer diameter in case of nonconstrained motion and 6 times in case of fixed installation.
Insulation tolerance ± 0,1
Sheath tolerance ± 0,2


Sections
Nominal section Max wire diameter Conductor diameter Insulation thickness Average sheath thickness Average diameter ± 0,1 Copper electric resistance 20°C Indicative weight CU Factor
(Nxmm2) (mm) (mm) (mm) (mm) (mm) (Ω/km) (kg/km) (kg/km)
1x10,00 0,31 3,895 3,00 NA 10.1 2,06 NA 96
1x16,00 0,31 5,40 3,00 NA 11.6 1,28 NA 153,6
1x25,00 0,31 6,50 3,10 NA 12.9 0,85 NA 240
1x35,00 0,31 7,60 3,40 NA 14.6 0,58 NA 336
1x50,00 0,31 9,30 3,40 NA 16.3 0,41 NA 480
1x70,00 0,31 10,80 3,70 NA 18.4 0,28 NA 672
1x95,00 0,31 12,50 4,10 NA 20.9 0,21 NA 912
1x120,00 0,31 0,000 4,60 NA 0 0,17 NA 959,99904