H05RN-F
Rubber cables
Flexible red copper-
certificates
-
Appliances Cables
Conditions of employment
Use in domestic premises, kitchens and offices, for ordinary duty applications and supplying appliances where cables are subject to low mechanical stresses (e.g. vacuum cleaners, cooking appliances, soldering irons, toasters, domestic portable tools, hand held inspection lamps).
Type of electrical conductor
Flexible red copper
Main rule
EN 50525-2-21
Conductor
EN 60228; IEC 60228
Self-extinguishing
EN 60332-1-2; IEC 60332-1-2
Oil resistance
EN 60811-404; IEC 60811-404
Description
Use in domestic premises, kitchens and offices, for ordinary duty applications and supplying appliances where cables are subject to low mechanical stresses (e.g. vacuum cleaners, cooking appliances, soldering irons, toasters, domestic portable tools, hand held inspection lamps).
Type of electrical conductor
Flexible red copper
Main rule
EN 50525-2-21
Conductor
EN 60228; IEC 60228
Self-extinguishing
EN 60332-1-2; IEC 60332-1-2
Oil resistance
EN 60811-404; IEC 60811-404
Description
Multicore, flexibile power cables for energy, rubber insulated, under mean polychloroprene sheath or other equivalent elastomer sheath.
More informations
Review number | n. 5 - 22/4/2015 |
Nominal tension | 300/500 V |
Type of insulation | EI4 |
Type of outer sheath | EM2 |
Color of the outer sheath | Black |
Operating temperature | -25° C | +60° C |
Short circuit temperature | 200° C on the conductor (max 5 sec.) |
Test voltage | 2000 V |
Cable marking | ELETTRO BRESCIA IEMMEQU <HAR> H05RN-F |
Minimum radius of curvature | 4 times the max. outer diameter for mobile service, 3 times in case of fixed laying. |
Insulation tolerance | ± 0,1 |
Sheath tolerance | ± 0,2 |
Insulation identification
number of cores | Insulation identification sequence |
3.00 | Yellow/Green-Blue-Brown |
2.00 | Blue-Brown |
4.00 | Yellow/Green-Blue-Brown-Black / Yellow/Green-Brown-Black-Grey |
Sections
The manufacturer reserves the right to modify all or part of the data shown in this catalogNominal section | Max wire diameter | Conductor diameter | Insulation thickness | Average sheath thickness | Minimum external diameter | Maximum external diameter | Copper electric resistance 20°C | Indicative weight | CU Factor |
(Nxmm2) | (mm) | (mm) | (mm) | (mm) | (mm) | (mm) | (Ω/km) | (kg/km) | (kg/km) |
2x0,75 | 0,21 | 1,052 | 0,60 | 0,80 | 5,7 | 7,4 | 26,00 | 58 | 14,4 |
2x1,00 | 0,21 | 1,215 | 0,60 | 0,90 | 6,1 | 8,0 | 19,50 | 69 | 19,2 |
3G0,75 | 0,21 | 1,052 | 0,60 | 0,90 | 6,2 | 8,1 | 26,00 | 72 | 21,6 |
3G1,00 | 0,21 | 1,215 | 0,60 | 0,90 | 6,5 | 8,5 | 19,50 | 83 | 28,8 |
4G0,75 | 0,21 | 1,052 | 0,60 | 0,90 | 6,8 | 8,8 | 26,00 | NA | 28,8 |
4G1,00 | 0,21 | 1,215 | 0,60 | 0,90 | 7,1 | 9,3 | 19,50 | NA | 38,4 |