| Multicore,
flexibile power cables for energy, rubber insulated, under mean
polychloroprene sheath or other equivalent elastomer sheath, with working
temperature of 90° C on the conductor. |
 |
| CEI 20-19 CENELEC HD 22 |
|
Nominal
section
|
Max.
diameter of the conductor wires
|
Insulator
mean thickness
|
Sheath
mean thickness
|
Outer
diameter min.
|
Outer
diameter max.
|
Cable
approximate weight
|
Max.
eletrical resistance at 20° C
|
|
n° x
mm²
|
mm
|
mm
|
mm
|
mm
|
mm
|
Kg/Km
|
Ohm/Km
|
|
2 x 0,75
|
0,21
|
0,6
|
0,8
|
5,7
|
7,4
|
58
|
26,7
|
|
2 x 1
|
0,21
|
0,6
|
0,9
|
6,1
|
8
|
69
|
20,0
|
|
3 G 0,75
|
0,21
|
0,6
|
0,9
|
6,2
|
8,1
|
72
|
26,7
|
|
3 G 1
|
0,21
|
0,6
|
0,9
|
6,5
|
8,5
|
83
|
20,2
|
|
| Allowable
currents for rubber insulated cables: |
|
Nominal
section of conductor
|
Allowable
current
With rubber insulation
|
|
mm²
|
Unipolar
|
Triple-pole
|
|
0,75
|
6
|
6
|
1
|
10
|
10
|
|
| Remarks:
These values apply in most cases. Further information are to be sought
for the unusual cases, e. g.: |
| 1 |
if
the room temperatures are too high, that is to say above 30° C. |
| 2 |
for
very long cables. |
| 3 |
in
presence of poor ventilation. |
| 4 |
when
the cables are used for the others purposes, for ex. inner wiring
harness of a device. |
|
| Applications: |
for
general use in domestic rooms, in the kitchen, offices and for
power supply of portable devices which afe subject to slight mechanical
stresses (for ex. aspirators, kitchen, utensils, welding, irons,
toasters). It is suitable also for permanent use outdoors, for
ordinary uses and applications. |
| Conductor: |
| single
copper wire, annealed, not tinned. |
| Insulation: |
| EI
7 rubber. |
| Sheath: |
| EM
7 rubber. |
| Marking: |
continuous
marking:
ELETTROBRESCIA IEMMEQU <HAR> H05BN4-F
on the sheath and/or
on the insulating material. |
| Max.
operating temperature: |
| 90° C
on the conductor. |
| Max.
temperature in case of short circuit: |
| (max.
duration 5 sec.): 200° C on the conductor. |
| Min.
bending radius: |
4
times the max. outer diameter for mobile service, 3 times in case
of fixed laying. |
| Max.
laying stress: |
| 15
N for mm² of
copper total section. |
| Core
colours: |
| bipolar |
blue-brown |
| triple-pole |
yellow/green-blue-brown |
|
| Sheath
colour: |
standard
= black.
Other colours can be supplied upon request and for quantities to
be agreed.
N.B.: the cable can be supplied upon request also
without ground conductor. |
|
| |
Elettrobrescia s.p.a.
sede Via Bulloni, 36 - 25040 - Camignone di Passirano (Bs)
Cod. Fisc. - Part. Iva e Reg. Imp. di Brescia N° 02402600981 - REA
446996